Notifications
You must be signed in to change notification settings - Fork 0
/
Copy pathpta8e16_16ch_pt100_read_loop.py
35 lines (29 loc) · 1.13 KB
/
pta8e16_16ch_pt100_read_loop.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
#!/usr/bin/env python3
import minimalmodbus
import time
pta8e16 = minimalmodbus.Instrument('COM3', 1) # port name, slave address (in decimal), controlled by the DIP switch onboard
pta8e16.serial.port # this is the serial port name
pta8e16.serial.baudrate = 9600 # Baud
pta8e16.serial.bytesize = 8
pta8e16.serial.parity = minimalmodbus.serial.PARITY_NONE
pta8e16.serial.stopbits = 1
pta8e16.serial.timeout = 0.2 # seconds
pta8e16.address # this is the slave address number
pta8e16.mode = minimalmodbus.MODE_RTU # rtu or ascii mode
pta8e16.clear_buffers_before_each_transaction = True
pta8e16.close_port_after_each_call = True
pta8e16.clear_buffers_before_each_transaction = True
sleep_time=0.2
i=0
while i!=100:
j=0;
while j!=16:
try:
print("CH",j+1,":", pta8e16.read_register(j,1,3)," C") #Read PT100 on channel j+1, memory address j, 1 decimal place, control code 3
except IOError:
print("Failed to read CH",j+1)
time.sleep(sleep_time)
j+=1
print("==========================")
i+=1
pta8e16.serial.close()