State | Min | Max | Unit | Mult | Name |
---|---|---|---|---|---|
exhaustTmp | 0 | 60 | °C | 0.1 | Exhaust pipe wall temperature |
batTime | 0 | 5999 | min | 1 | batTime; a negative value indicates a discharging time, and positive value indicates a charging time |
tempWater | 0 | 60 | °C | 0.1 | Water temperature of the ice making zone |
A12Val | 0 | 15 | V | 0.001 | 12 V auxiliary supply voltage |
motorCur | 0 | 60 | A | 0.001 | Motor Current |
tmpM | -20 | 60 | °C | 1 | Combined temperature zone temperature |
icePercent | 0 | 100 | % | 1 | Ice making progress |
powerBatInTime | 0 | n/a | min | 0.0166667 | Duration of battery pack in place |
ambientTmp | 0 | 60 | °C | 0.1 | Ambient temperature |
coolZoneSingleTime | 0 | n/a | min | 0.0166667 | Single temperature zone duration |
tmpAver | -20 | 60 | C | 0.1 | Real-time temperature of single temperature zone |
batPct | 0 | 100 | % | 1 | Battery level |
iceTmTag | 0 | 1440 | min | 1 | The ice making target time (used for app and LCD effect display) |
coolCoverTime | 0 | n/a | min | 0.0166667 | Duration of cooling zone being opened |
powerBatOutTime | 0 | n/a | min | 0.0166667 | Duration of battery pack not in place |
chargeWorkTime | 0 | n/a | min | 0.0166667 | Duration of working while charging |
motorVol | 0 | 60 | V | 0.001 | Motor voltage |
coolZoneDoubleTime | 0 | n/a | min | 0.0166667 | Duration of dual temperature zone |
motorSpeed | 0 | 3600 | rpm | 1 | Motor speed |
motorWat | 0 | 600 | W | 1 | Motor power |
iceTm | 0 | 1440 | min | 1 | Duration of the current ice making (for app and LCD effect display) |
tmpR | -20 | 60 | °C | 0.11 | Actual Right temperature zone value |
tmpL | -20 | 60 | °C | 1 | Actual temperature of the left temperature zone |
State | Name |
---|---|
tempCoolTime | Length of time when the actual temperature of the cooling zone falls in each interval: COOL_ ZONE_ MAX*TEMP_ COOL_ MAX |
appSensorAdv | Duration of sensor blocking: SENSOR_ADV_MAX |
errorTimePower | Duration of each type of fault in the POWER module: ERROR_MAX_POWER |
tempIceTime | Length of time when temperature of the ice-making zone falls in each interval: TEMP_ICE_MAX |
networkTypeTime | Duration of being networked: NETWORK_TYPE_MAX |
powerXt60Time | Duration of each type of power supply on XT60: POWER_TYPE_MAX |
chargeXt60Time | Duration of each type of charging power supply on XT60: POWER_TYPE_MAX |
errorTimeBms | Duration of each type of fault in BMS module: ERROR_MAX_BMS |
appOpTimeBlTime | Screen timeout set through app: BL_TIME_MAX |
errorTimePd | Duration of each type of fault in PD module: ERROR_MAX_PD |
workFsmTime | Running duration of state machine under each state: USER_BEHAVIOR_FSM_MAX |
workModeTime | Running duration of each work mode; WORK_MODE_MAX |
tempAmbientTime | Length of time when ambient temperature falls in each interval: TEMP_AMBIENT_MAX |
tempCoolSetTime | Length of time when the set temperature of the cooling zone falls in each interval: COOL_ZONE_MAX*TEMP_COOL_SET_MAX |
buttonLong | Count of long presses: USER_BEHAVIOR_BUTTON_MAX |
networkTypeCount | Count of being networked: NETWORK_TYPE_MAX |
powerXt60Count | Count of each type of power supply on XT60: POWER_TYPE_MAX |
errorCountPower | Count of each type of fault in POWER module: ERROR_MAX_POWER |
workFsmCount | Count of entering each state of state machine: USER_BEHAVIOR_FSM_MAX |
errorCountBldc | Count of each type of fault in BLDC module: ERROR_MAX_BLDC |
workModeCount | Count of entering each work mode; WORK_MODE_MAX |
errorCountBms | Count of each type of fault in BMS module: ERROR_MAX_PD |
chargeXt60Count | Count of each type of charging power supply on XT60: POWER_TYPE_MAX |
appOpCountWorkMode | Count of each work mode set through app: WORK_MODE_MAX |
appOpCountBlTime | Count of setting different screen timeout through app: BL_TIME_MAX |
errorCountPd | Count of each fault in PD module: ERROR_MAX_PD |
buttonShort | Count of short pressings: USER_BEHAVIOR_BUTTON_MAX |
errorTimeBldc | array errors? |
State | Min | Max | Unit | Mult | Name | cmd |
---|---|---|---|---|---|---|
tmpMSet | -20 | 50 | °C | 0.01 | Set Temperature of the middle temperature zone | {valName:tmpM,moduleType:1,operateType:temp,params:{tmpR:-19,tmpL:0,tmpM:0}} |
tmpRSet | -20 | 50 | °C | 0.01 | Set Temperature of the right temperature zone (valid when partition is inserted) | {valName:tmpR,moduleType:1,operateType:temp,params:{tmpR:-19,tmpL:0,tmpM:0}} |
tmpLSet | -20 | 50 | °C | 0.01 | Set Temperature of the left temperature zone (valid when partition is inserted) | {valName:tmpL,moduleType:1,operateType:temp,params:{tmpR:-19,tmpL:0,tmpM:0}} |
powerPbLevel | 0 | 2 | level | 1 | Battery protection level 0: Low; 1: Medium; 2: High | {valName:level,moduleType:1,operateType:protectBat,params:{state:1,level:0}} |
blTime | 0 | 3600 | s | 1 | Screen timeout | {valName:time,moduleType:1,operateType:blTime,params:{time:600}} |
State | Name |
---|---|
errBms | BMS fault code |
errPd | PD fault code |
errBldc | BLDC fault code |
emsChgFlg | EMS charging flag |
errLcd | Fault code displayed on LCD screen |
threeWayState | Refrigerant flow direction flag bit |
flagTwoZone | Partition detection |
errCode | Error code |
errPwr | POWER fault code |
coolZoneDoubleCount | Count of dual temperature zones |
coolCoverCount | Count of cooling zone openings |
appOpCountDeIce | Count of ice detaching through app |
dntMakeIceDevice | Count of pressing the ice making button when ice making is disabled |
appOpCountBeepOff | Count of turning off buzzer through app |
appOpCountPowerOn | Count of powering on through app |
countinueMakeIceMax | Maximum count of consecutive ice making |
appOpCountPowerOff | Count of powering off through app |
appOpCountDntMakeIce | Count of ice making through app when ice making is disabled |
powerBatInCount | Count of battery pack in place |
makeIceCount | Total count of ice making |
chargeWorkCount | Count of working while charging |
coolZoneSingleCount | Count of single temperature zone |
countinueMakeIceAve | Average count of consecutive ice making actions |
appOpCountTempUnitC | Count of setting degrees in Celsius through app |
appOpCountTempUnitF | Count of setting degrees in Fahrenheit through app |
appOpCountBeepOn | Count of enabling buzzer through app |
err | PD error |
appOpCountMakeIce | Count of ice making through app? |
State | Name | values |
---|---|---|
iceMkMode | Large/small ice cube status | {0:Small ice cube (in preparation),1:Large ice cube (in preparation),2:Small ice cube (ice making in progress; cannot be changed),3:Large ice cube (ice making in progress)} |
fsmState | Real-time running status | {0:Small ice cube (in preparation)?,1:Large ice cube (in preparation)?,2:Small ice cube (ice making in progress; cannot be changed)?,3:Large ice cube (ice making in progress)?,4:Detaching ice,5:Detaching completed} |
motorWait | Waiting for compressor: | {0:No need to wait,1:Need to wait} |
pwrState | pwrState | {0:Powered off,1:Powered on} |
bldcDntWork | Compressor work limit | {0:Allow to work,1:Do not allow to work} |
waterLine | Ice making zone water level: 0-3 levels | {0:OK?} |
flagAmbintReady | Ambient temperature reliability | {0:Unreliable,1:Reliable} |
batFlag | Battery pack in-place status | {0:Not in place,1:In place} |
xt150InState | xt150InState | {0:no input,1:has input} |
doorStat | Door status detection | {0:Closed,1:Open} |
runState | Operating status | {0:Normal (24 V output, 40 V output),1:Charging suspended (or when there is no input) (24 V off, 40 V output),2:Standby (24 V off, 40 V off)} |
chgType | Charger type //Charger type | {0:NULL,1:XT150 charging,2:Adapter charging (hardware detection),3:Car charging (hardware detection),4:Solar panel charging (hardware detection),5:Car charging (software detection),6:Solar panel charging (software detection),7:Input source cannot be identified (0xff): the charging cable is connected, but it actually does not work due to charging being disabled} |
sensor | Sensor status; refer to @ST_SENSOR for data explanation; bit 1: Error; bit 0: Normal | {0:Normal,2:Error} |
xt60InState | xt60 connection status | {0:no input,1:has input} |
iceAlert | Ice taking reminder | {0:Do not remind,1:Remind} |
carBatLow | Car charger battery protection reminder | {0:Do not remind,1:Remind} |
bmsInFlag | BMS in-place flag, detected through BMS->PD heartbeat packet | {0:Not in place,1:In place} |
bldcDntIce | Ice making limit on compressor | {0:Ice making is allowed,1:Ice making is not allowed} |
warnInfo | Warning | {0:no warning?,1:overtemperature,2:Under-temperature,4:Overload,8:Charging error,16:Fan error,32:BLCD communication error} |
fanLvl | Fan level | {0:non-rotation,1:Level 1,2:Level 2,3:Level3,4:Level 4,5:Level 5} |
deiceAct | Deice Active? | {0:inactive,1:active} |
State | off | on | Name | cmd |
---|---|---|---|---|
iceMode | Disable | Enable | Ice Making | {valName:enable,moduleType:1,operateType:iceMake,params:{enable:1,iceShape:1}} |
iceShape | small cubes | large cubes | Ice Shape | {valName:iceShape,moduleType:1,operateType:iceMake,params:{enable:1,iceShape:1}} |
iceDetach | Disable | Enable | Ice Detaching | {valName:enable,moduleType:1,operateType:deIce,params:{enable:0}} |
coolMode | Normal | Eco | cool Mode | {valName:mode,moduleType:1,operateType:ecoMode,params:{mode:1}} |
sensorAdv | Unblocked | Blocked | Sensor detection blocking. Refer to @ST_SENSOR for data explanation. Bit: 1: Blocked; 0: Unblocked. | {valName:senseorAdv,moduleType:1,operateType:sensorAdv,params:{sensorAdv:1}} |
beepEn | Disabled | Enabled | Buzzer enabling status | {valName:flag,moduleType:1,operateType:beepEn,params:{flag:1}} |
pwrPbEn | Disable | Enable | Battery protection switch | {valName:state,moduleType:1,operateType:protectBat,params:{state:1,level:0}} |
tmpUnit | Celsius | Fahrenheit | Temperature Unit | {valName:unit,moduleType:1,operateType:tmpUnit,params:{unit:0}} |
State | Min | Max | Unit | Mult | Name |
---|---|---|---|---|---|
designCap | 0 | 13800 | mAh | 1 | Design capacity |
f32ShowSoc | 0 | 100 | % | 1 | SOC |
minMosTmp | 0 | 80 | °C | 1 | Minimum MOS temperature |
vol | 0 | 60 | V | 0.001 | Voltage |
fullCap | 0 | 13800 | mAh | 1 | Full capacity |
remainCap | 0 | 13800 | mAh | 1 | Remaining capacity |
tmp | 0 | 60 | °C | 1 | Temperature |
outWatts | 0 | 500 | W | 1 | Output power |
cycles | 0 | 6000 | 1 | Number of cycles | |
minCellVol | 0 | 60 | V | 0.001 | Minimum cell voltage |
maxCellVol | 0 | 60 | V | 0.001 | Maximum cell voltage |
maxMosTmp | 0 | 80 | °C | 1 | Maximum MOS temperature |
inWatts | 0 | 600 | W | 1 | Input power |
soc | 0 | 100 | % | 1 | Remaining battery percentage |
tagChgAmp | 0 | 100 | A | 0.0001 | Target charging current |
minCellTmp | 0 | 60 | °C | 1 | Minimum cell temperature |
maxCellTmp | 0 | 60 | °C | 1 | Maximum cell temperature |
remainTime | 0 | 143999 | min | 1 | Time remaining |
amp | 0 | 50 | A | 0.001 | Current |
State | Name |
---|---|
bmsFault | BMS permanent fault |
num | BMS number |
err | Global error code |
bqStatReg | BQ hardware protection register |
ver | System version |
soh | Health status |
State | Name | values |
---|---|---|
type | BMS type | {1:Lithium battery,2:Oil-powered} |
cellId | Battery capacity type | {1:2.5 Ah per battery,2:2 Ah per battery} |
openBmsIdx | Battery pack status | {0:Not enabled,1:Enabled} |
State | Min | Max | Unit | Mult | Name |
---|---|---|---|---|---|
closeOilEbSocMax | 60 | 100 | % | 1 | SOC for turning off Smart Generator |
chgVol | 0 | 150 | V | 0.001 | Charging voltage |
dsgRemain | 0 | 5999 | min | 1 | Remaining discharging time |
maxAvailNum | 0 | 40000 | mAh | 1 | Maximum available quantity |
paraVolMax | 0 | 60 | V | 0.001 | Maximum parallel voltage |
paraVolMin | 0 | 60 | V | 0.001 | Minimum parallel voltage |
lcdSoc | 0 | 100 | % | 1 | SoC value displayed on LCD |
chgRemain | 0 | 5999 | min | 1 | Remaining charging time |
openOilEbSocMin | 0 | 30 | % | 1 | SoC for turning on Smart Generator |
minDsgSoc | 0 | 30 | % | 1 | Minimum discharging SOC |
maxChgSoc | 60 | 100 | % | 1 | Maximum charging SOC |
f32LcdSoc | 0 | 100 | % | 1 | SOC on LCD |
chgAmp | 0 | 100 | A | 0.0001 | Charging current |
State | Name |
---|---|
bmsIsConnt | BMS online signal |
State | Name |
---|---|
openBmsIdx | Open BMS index |
upsFlag | UPS mode enable flag |
bmsModel | BMS model |
State | Name | values |
---|---|---|
warnState | BMS warning state | {0:no warning?,1:hi_temp,2:low_temp,4:overload,8:chg_flag} |
dsgCmd | Discharge switch | {0:off,1:on,2:2?} |
emsFlag | ems Flag | {0:sleep,1:normal} |
chgCmd | Charge switch | {0:off,1:on,2:2?} |
fanLvl | Fan level | {0:non-rotation,1:Level 1,2:Level 2,3:Level3,4:Level 4,5:Level 5} |
chgState | Charging state | {0:disabled,1:CC,2:CV,3:UPS,4:PARA 0x55: Charging error} |