Release date | Version | Stationary logger ProgSig |
Mobile logger ProgSig |
---|---|---|---|
2018 June 5 | 0.1 | 44463 | 40156 |
2018 July 10 | 1.0 | 47848 | 8408 |
2018 July 20 | 2.0 | 18988 | 8408 |
- By user special request, add grab sample of sonic anemometer components to 1-minute data table
- Expose GPS position to users on front panel display. Shows minutes component of lat/long since degrees expected to remain relatively constant.
- FIX: record all four aggregated wind values for sonic anemometer. Previously
only first value (
csat3b_wnd_spd
) was retained in tableminutely
. (Data not recorded can be reconstructed from 10Hz anemometer data set.) - FIX: add missing closing paren (no impact on program operation)
- Track datalogger wiring panel temperature, for quality assurance: adds new
column
logger_panel_tmpr
to end of 1-min data tables - FIX: step back custom menu so users first see a timestamp & card status, then press any key to obtain custom menu. Also, for stationary site only (because user can change azimuth value using keyboard display), hide present values behind a "View data" submenu
- Initial release used for validating testing and the following field sampling
events:
- June 12, 2018
- June 22, 2018