Skip to content

2019 12 18_meeting

Michael Wetter edited this page Dec 17, 2019 · 1 revision

SOEP Coordination meeting

Date: December 18, 2019, 8:15am-9am Pacific Times

The purpose of this meeting is to coordinate the Modelica integration for SOEP.

Meeting information

Join from PC, Mac, Linux, iOS or Android: https://lbnl.zoom.us/my/mwetter

Or iPhone one-tap (US Toll): +14086380968,6614042296# or +16465588656,6614042296#

Or Telephone:
Dial: +1 408 638 0968 (US Toll) or +1 646 558 8656 (US Toll) Meeting ID: 661 404 2296 International numbers available: https://lbnl.zoom.us/zoomconference?m=_h5BuJ686mPy3rWEyKf4NROxLaeOV5J8

Agenda

  1. Previous action items.
  2. Michael: SimBuild paper.
  3. Kyle: NREL/Modelon subcontract update.
  4. Kyle, Michael: Refactoring room air heat and mass balance.
  5. Kyle, Michael: EnergyPlus I/O variables.
  6. Stuart: FMI-QSS.
  7. Kyle, Michael: Optimica license protection.
  8. Jianjun: JSON representation for OS front-end to Modelica
  9. Other items

Participants

to be updated

Yanfei Li
Jianjun Hu
Antoine Gautier
Stuart Mentzer
Amir Roth
Bo Shen
Hubertus Tummescheit
Michael Wetter

Minutes

SimBuild paper

Paper is developed at https://bitbucket.org/berkeleylab/srg-soep-papers/src/master/, see https://bitbucket.org/berkeleylab/srg-soep-papers/src/master/2020-simbuild/1_manuscript/

Last changes done by Amir and Michael.

Final submission to conference due Fr Dec 20.

Numerical investigations

No discussion.

No work conducted.

Refactoring room air balance

Branch issue1129_energyPlus_zone works for multiple buildings for JModelica, Dymola and OpenModelica. This has the FMI interface now.

Issues are at https://github.com/lbl-srg/modelica-buildings/issues?q=is%3Aissue+is%3Aopen+label%3Aspawn

Next, work on

const size_t nCat = fmi2_import_get_log_categories_num(bui->fmu); * Kyle to create installer package for all three platforms.

Contract:

  1. All zones in the idf file must have a zone model in Modelica. Otherwise the simulation stops with an error.
  2. If there is an HVAC system in the idf file, then EnergyPlus issues a warning, the EnergyPlus HVAC system is not simulated, but the coupled EnergyPlus/Modelica simulation proceeds.
  3. For the EnergyPlus envelope, either the CTF transfer function or the finite difference method can be used.

FMI-QSS

No discussion.

Stuart to work on updating 3rd order QSS with numerical differentiation.

Next will be work on performance estimation assuming we would have automatic differentiation.

CI testing (funnel)

No discussions.

Next:

  • Work on experiment specification.

Optimica license protection

No discussion.

Potential paths: Check diff to frozen library. Allow n models to be changed. Upgrade path to full OCT version (with access to cloud version in an integrated way).

Need to define the different use cases and work flows.

Use of python API makes protection much easier, is sufficient unless interactive mode is needed. Java API would be needed for interactive mode.

JSON representation for OS front-end to Modelica

No discussion.

Jianjun to work on modelica-json parsing in Modelica rather than CDL mode.

Ongoing is dealing with replaceable models.

Other items

None.

New action items

See next steps under "Refactoring room air balance".

Previous action items

Michael to set up simple control example for QSS with time sampling, PI and hysteresis.

Michael will look into making dp of pressure drop elements a state rather than p using stateSelect.

Agnes to get back regarding debug information for user for nonlinear solver.

Clone this wiki locally