Date: October 7, 2020, 8:15am-9am Pacific Times
The purpose of this meeting is to coordinate the Modelica integration for SOEP.
Join from PC, Mac, Linux, iOS or Android: https://lbnl.zoom.us/my/mwetter
Or iPhone one-tap (US Toll): +14086380968,6614042296# or +16465588656,6614042296#
- Or Telephone:
- Dial: +1 408 638 0968 (US Toll) or +1 646 558 8656 (US Toll) Meeting ID: 661 404 2296 International numbers available: https://lbnl.zoom.us/zoomconference?m=_h5BuJ686mPy3rWEyKf4NROxLaeOV5J8
- Previous action items.
- Release of Spawn coupling.
- Kyle, Michael: Refactoring room air heat and mass balance.
- Kyle, Michael: EnergyPlus I/O variables.
- Michael, Kyle: Support for radiant systems.
- Stuart: FMI-QSS.
- Kyle, Michael: Optimica license protection.
- Jianjun: JSON representation for OS front-end to Modelica
- Other items
See milestones. Linux 64 and Windows 64 (if tests on Windows 64 don't show new issues).
Branch issue1129_energyPlus_zone works for multiple buildings for JModelica, Dymola and OpenModelica.
Issues are at https://github.com/lbl-srg/modelica-buildings/issues?q=is%3Aissue+is%3Aopen+label%3Aspawn
Next, work on
- Kyle to work on support of QRad_flow, https://github.com/lbl-srg/modelica-buildings/issues/1954
- Kyle to address https://github.com/lbl-srg/modelica-buildings/issues/2132#issuecomment-693673707
- [For FY21] Kyle to fix schedule: https://github.com/lbl-srg/modelica-buildings/issues/2000
- (Kyle either fixes it, or proposes new wording for https://lbl-srg.github.io/soep/softwareArchitecture.html#sending-input-to-energyplus)
- [For FY21] Kyle to look into numerical instability (walls may be initialized to wrong temperature). See for example Experimental/EnergyPlus/Examples/VAVReheatRefBldgSmallOffice/FloorOpenLoop. The temperature in the attic should not raise in the first hour. (Pending since Nov. 2019)
- Kyle to provide list of supported output variables, and statement of how non-supported output variables are handled, https://github.com/NREL/Spawn/commit/e443d634ab4f15d5d69e487fcc206c7d4f403353
- Michael/Milica to use thermal zones in larger model, https://github.com/lbl-srg/modelica-buildings/pull/1663
- Kyle to move model.spawn to resources folder. It has the same information as ModelicaBuildingsEnergyPlus.json (other than that some path are absolute and some are relative in model.spawn).
LBL AOP 6/30: Couple controls I/O. (Ready.)
LBL AOP 9/30 (go/no-go): Release that can couple Modelica-based control to E+. (Linux is ready to be merged to master.)
Kyle to work on emitting all EnergyPlus objects that are supported by Spawn.
- If there is a thermal zone in Modelica, then there need to be a Zone object in the idf file. Otherwise the simulation stops with an error. EnergyPlus reports a Fatal Error to its error file and to the FMI API call.
- If there is an Zone object in the idf file but no thermal zone in Modelica for this EnergyPlus zone, then EnergyPlus simulates the zone using free floating temperature. There is no HVAC system, but may be internal gains. EnergyPlus reports an information message to its error file and to the FMI API call.
- All HVAC objects in the idf file will be removed by the Spawn executable before it writes the idf file to the FMU.
- For the EnergyPlus envelope, either the CTF transfer function or the finite difference method can be used.
- Output variables and EMS actuators need not be present in the idf file.
Specfication at https://lbl-srg.github.io/soep/softwareArchitecture.html#coupling-of-a-zone-surface.
To be done in FY 21.
Stuart works on estimate for how much function calls are reduced if there is no numerical noise from derivative approximation.
OS X to be done in FY 21.
No discussions.
Kyle to look into license protection provided by Modelon.
No discussions.
To do:
- Address TypeError issues reported in https://github.com/lbl-srg/modelica-json/issues/106.
- Handling replaceable models.
None.
Kyle to prioritize implementation of QRad_flow, https://github.com/lbl-srg/modelica-buildings/issues/1954 and Windows testing.
Michael to work on Windows testing.
Michael to keep working with Modelon on making dp of pressure drop elements a state rather than p using stateSelect.
Kyle to look into license protection provided by Modelon.